Pulse Oximeters - Medical and Hospital Equipment

Portable pulse oximeters measure peripheral oxygen saturation (SpO2) and pulse rate using a non-invasive optical sensor. They are used in shipboard hospitals, sick bays, offshore platforms, and emergency medical response kits.

ProShipWorks provides end-to-end support to source and supply Pulse Oximeters for marine vessels, ship operators, industrial facilities, maintenance teams and procurement departments.

Last updated:

Product Information

Product Name Pulse Oximeters
Product Category Medical and Hospital Equipment
Product Reference 1577
Brands / Manufacturers Masimo, Nonin Medical, Philips
Unit of Measure Piece

Key Features

Key Feature
1.   Non-invasive SpO2 and pulse-rate measurement
2.   Finger, reusable, or disposable sensors
3.   Battery-powered portable operation
4.   Audible and visual alarms on applicable models
5.   Suitable for medical assessment and patient monitoring

Applications of Pulse Oximeters

Application
1.  Ship hospital and sick-bay patient assessment
2.  Emergency response and first aid onboard vessels
3.  Monitoring patients during transport, treatment, or evacuation

Models & Manufacturers

Model Manufacturer
Rad-5 Masimo
Rad-57 Masimo
2500A PalmSAT Nonin Medical

Technical Specifications

Model Specification Value Unit
Rad-5 SpO2 measurement range 1-100 %
Rad-5 Pulse-rate range 25-240 bpm
Rad-57 SpO2 measurement range 1-100 %
Rad-57 Pulse-rate range 25-240 bpm
2500A PalmSAT SpO2 measurement range 0-100 %
2500A PalmSAT Pulse-rate range 18-321 bpm

Standards, Certifications & Class Approval

Review the available standards and approval information relevant to the product. Actual certification, material traceability, inspection and classification requirements depend on the product type, intended application and purchasing specification.

Applicable Standards & Certification Applicable standards commonly include IEC 60601-1 for basic safety, IEC 60601-1-2 for electromagnetic compatibility, and ISO 80601-2-61 for pulse oximeter equipment. Certification depends on the specific model and market.
Class Approval Individual portable pulse oximeters are not generally type-approved by DNV, ABS, Lloyd's Register, BV, or ClassNK. Acceptance onboard may depend on flag-state medical requirements, vessel medical inventory specifications, and the manufacturer's regulatory approvals.

Installation, Maintenance & Safety Information

Installation Notes No fixed installation is normally required. Insert approved batteries, connect the correct sensor, and verify operation using the manufacturer's procedure. Keep the device accessible in the ship sick bay or medical locker.
Maintenance Tips Inspect the housing, display, cable, and sensor before use. Clean and disinfect according to the manufacturer's instructions. Replace damaged sensors and batteries, and perform functional checks or calibration verification at the recommended intervals.
Safety Notes Use only approved sensors and accessories. Confirm adequate peripheral perfusion and correct sensor placement; motion, low perfusion, nail products, ambient light, and carbon monoxide exposure can affect readings. Do not use the reading as the sole basis for diagnosis or treatment.

Request a Quote for Pulse Oximeters

Contact ProShipWorks for marine or industrial product sourcing, quotations and delivery.

  • Vessel name and IMO number
  • ETA / vessel schedule
  • Berth or vessel location
  • Required quantity
  • Preferred delivery window
  • Shipping agent contact details

Why ProShipWorks?

Trusted & Professional Service

Experienced maritime professionals focused on quality, safety and dependable service execution.

24/7 Rapid Response

Fast response for planned and urgent vessel requirements, whenever support is needed.

Unbeatable Prices

Cost-effective marine services with competitive and transparent pricing for vessel requirements.

Port & Anchorage Coverage

Reliable marine service support across ports, anchorages and offshore locations.